navigationbar

 
ELECTRONIC INSTRUMENTS: BRAVO ONE / TWO


MAIN FEATURES: BRAVO ONE BRAVO TWO
- design: modified Aldane algorithm, tissues examined n°12 n°12
- available programs and useable by the diver: 3+1(air) 3+1(air)
- connection to a P.C.: NO NO
- battery (6 volts) changeable by the diver: YES YES
- number of dives possible with the batteries supplied: 30-40 150
- constant tissue status graphics display: YES YES
- acoustic alarm NO YES
- dive simulator YES YES
- precision +/- 1% depth gauge - accuracy to 0.375 m    
- operating range for multilevel and successive dives in metres 0-82 0-82
- alarm messages: CAUTION - DESCENT - WARNING- YES YES
- low battery warning YES YES
- Emergency red LED in event of LCD damage YES YES
- decompression control at depths of 3-6-9-12 etc., (no exceed) YES YES
- control of successive dives, tissues involved: n°12 n°12
- large LCD and characters for easy reading
- self-calibrating automatic and/or manual switch ON YES YES
- multilevel dive control algorithm with T.I.R. 45: NO NO
- cylinder pressure and remaining air time: NO NO
DATA DISPLAYED UNDERWATER: BRAVO ONE BRAVO TWO
- current depth and max. depth reached;
- total dive time and remaining non decompression time;
- total decompression time and stop time at first decompression point;
- total ascent time inc. decompression stop time at various depths;
- decompression depth in metres or feet from 3 to 18 metres with alarm message (DESCEND);
- ascent time and/or deco-stop depth exceeded alarm (DESCEND);
- descent time and/or operating limits exceeded (WARNING);
- low battery warning;
- emergency ascent warning (red LED);
- NON decompression dive completed warning (CAUTION);
- oxygen lung toxicity unit graphics.
NO NO
- pressione delle bombole e tempo residuo in funzione del consumo, NO NO
DATA DISPLAYED ON THE SURFACE: BRAVO ONE BRAVO TWO
- number of completed dives and next dive number.
- surface time, total desaturation time, time needed before flying.
- maximum depth during last dive.
- 4 automatic safety programs triggered if dive reaches algorithm limit.
- instrument operating limits exceeded during last dive data.
- next dive safety curve scrolling;
- low battery and no fly data;
- deco-stop not performed data;
- max. depth, dive time and surface time for last sixteen dives;
- depth record, total number of dives, total dive hours;
- maximum partial oxygen exposure data (Nitrox);
NO NO
- oxygen lung toxicity unit graphics; NO NO
- tissue status and/or current desaturation graphics;
- next and/or demonstration dive simulation; YES YES
- cylinder pressure NO NO


 



Via Tosarelli, 340/G - 40055 Villanova di Castenaso, Bologna - Italia-